Lightning Surge Protectors, Lightning Arrestors, Lightning Surge Capacitors
and lightning Data Line Circuit Protectors

Surge Protection:

Lightning rods alone will not protect electronic equipment. Surge protection is necessary to help protect sensitive electronic equipment from damaging lightning currents. Surge protection is recommended on the building's main electrical distribution panel, branch panels and electrical outlets where electronics will be plugged in (i.e. outlet surge protection, surge protection strips, etc.). Also, surge protection should be installed at communication/data (telephone, fax etc.), at building entrance (i.e. coaxial cables, cable TV, satellite dish, antennas, alarm systems etc.).

UL Master Label lightning protection system requires that the lightning surge protector for the main electrical distribution panel shall be UL listed and 1449 Edition 3 Listed.

surge protector package delta surge protectors

Packaged Protection

Save 10 % when you purchase a lightning arrestor (or surge protector), surge capacitor and circuit protector as a complete package!

Residential PackagesCommercial Packages
Residential Package #2 - PR2
Voltage Rating:0-300 volts Single Phase
Includes LA302R, CA302R, and TA304

Commercial Package #1 - PC1
Voltage Rating: 0-300 volts Single Phase
Includes LA302, CA302R and TA304

Residential Package #2 - PR2
Voltage Rating: 0-300 volts Three Phase
Includes LA303, CA603-R, and TA304

Commercial Package #2 - PC2
Voltage Rating: 0-300 volts Three Phase
Includes LA303, CA603-R, and TA30

  Commercial Package #3 - PC3
Voltage Rating: 0-600 volts Three Phase
Includes LA603, CA603, and TA304

 

Lightning Arrestors

Lightning Arrestors

Lightning arrestors (also known as surge protectors) protect electrical components and provide immediate, reliable protection against high voltage surges on buildings or power lines, that can cause electrical fires. These units will last a lifetime, except in the extreme cases of rare excess surges. A breaker box is incapable of providing protection against a "lightning fast" surge of electricity because by the time your breaker has switched off, the surge has already done its damage. Although a lightning arrestor helps to prevent high voltage spikes from infiltrating your circuits, it does not protect against the common smaller surges, which is the job of surge Capacitors.

Lightning Arrestors
Lightning Arrestor - LA302R
Voltage Rating: 0-300 volts
2-1/4" High, 2-1/4" Diameter
3 wire single phase. 60,000 amps maximum current 2,000 joules per pole Unlimited number of surges. No leak current at double the rated voltage. PVC case material.

Lightning Arrestor - LA302
Voltage Rating: 125-250 volts
4-1/4", 2-1/4" Diameter
Single Phase 3 Wire Service. 100,000 amps maximum current 3000 joules per pole Unlimited number of surges. No leak current at double the rated voltage. PVC case material.

Lightning Arrestor - LA303
Voltage Rating: 0-250 volt
4-1/4", 2-1/4" Diameter
3 Phase 3 or 4 Wire Service

Lightning Arrestor - LA603
Voltage Rating: 0-650 volts
4-1/3", 2-1/4" Diameter
4 wire three phase


surge capacitors

Lightning Surge Capacitors

Surge Capacitors protect your building or power lines against smaller surges which occur every day when appliances turn on and off due to varying levels of current, or when power to a local grid is lost, or regained, which brings on these surges. The constant wear-and-tear of these surges can eventually permanently damage delicate electrical components. While surge capacitors are fully capable of guarding against the smaller fluctuations in current and voltage, they are unable to provide protection against large voltage spikes. Therefore, you should have both a lightning arrestor and a surge capacitor installed in your home or business.

Surge Capacitors
Surge Capacitor - CA302R
Voltage Rating: 0-300 volts
4-1/2" High, 2-1/4" Diameter
This unit is designed for light duty service such as single phase commercial and residential service entrance panels

Surge Capacitor - CA603R
Voltage Rating: 0-600 volt
4-1/2" High, 2-1/4" Diameter
This unit is designed for regular duty service such as commercial three phase service entrance panels.

Surge Capacitor - CA603
Voltage Rating: 0-650 volts
5-3/4" High, 3-1/2" Diameter
This unit is designed for heavy duty service such as motor installations.


Circuit Protectors

Lightning Data Line Circuit Protectors

The final line of defense in surge protectors is the Data Line Circuit Protector. This unit guards against electrical surges in telephone and data lines, which are often left connected to computers and televisions during thunderstorms. Hundreds of people talking on "land-line" telephones are killed every year during electrical storms by current coming straight through the telephone. A Data Line Circuit Protector affords some protection against these often overlooked and potentially lethal surges.

Lightning Data Line Circuit Protectors
Data Line Circuit Protectors - TA304
1.9" X 1.6"
Two pair, data line circuit protector w/separate ground. Helps prevent surge damage to audio pairs, data lines, modems, local area networks, computers, fax machines, alarm systems, and telephones. Weatherproof Enclosure.

To place an order please call or fill out this Quote Form.
We Accept Visa, Mastercard and Discover Cards:
Credit Card Logos
KLP, Inc. Montana
Email:
PO Box 209
St. Ignatius
MT (Montana), 59865
Phone: 406-745-3800,
Fax: 406-745-3820
KLP, Inc. Florida
Email:
11 Santo Court
Fort Myers
FL (Florida), 33912
Cell: 239-470-4880
KLP, Inc. Minnesota
Email:
1670 Greer Ave. N.W.
Maple Lake
MN (Minnesota), 55358
Phone:763-229-8313
KLP, Inc.
Atlanta, Georgia

Email:
Phone: 406-745-3800,
Fax: 406-745-3820

Translate this Page in any language